Products Categories
Contact

Hofmann (Beijing) Engineering Technology Co.,Ltd

Add:6F, East International Building, No.2 DongZhiMen Outside Street, DongCheng District, Beijing

Tel:+86-10-84479336

Fax:+86-10-84479336

Email:service@hfmphe.com

Web:www.hfmphe.com

Plate for Hisaka Plate Heat Exchanger

The plates for Hisaka plate heat exchangers are specially selected from various patterns so as to achieve optimum area and cost effective heat exchanger for each- unit. These plates can be classified into three patterns, namely. 1. HERRINGBONE PATTERN such as LX-, UX-, RX-, WX-, and SX-series 2....

Send Inquiry Chat Now

The plates for Hisaka plate heat exchangers are specially selected from various patterns so as to achieve optimum area and cost effective heat exchanger for each- unit.  These plates can be classified into three patterns, namely. 1. HERRINGBONE PATTERN such as LX-, UX-, RX-, WX-, and SX-series 2. WASH BOARD PATTERN such as EX-series 3. SPECIAL WAVE PATTERN such as GX-, and YX-series


1.  HERRINGBONE PATTERN

The herringbone design in LX-series has corrugations with pitch which is rough and deep. In SX-series, the pitch is fine and shallow, hence LX-series are used in application  where low NTU is required, and SX-series are best suited for high NTU applica- tion. UX/RX-series is in between LX-series and SX-series. NTU = Hot temp in-Hot temp out LMTD NTU : Number of heat Transfer Unit LMTD : Logarithmic  Mean Temp. Difference NTU of 1.5 and less is generally referred to as low NTU, and 3.0 and above is considered as high NTU

img11354.jpg

Even in the same series, the heat transfer characteristic is different due to plate pattern angle. H plate is suited to high NTU, while L plate to low NTU. When the plates  corrugated in H plate and L plate can be mixed together in a unit, intermediate ther- mal characteristics can be achieved.

img12656.jpg


2.  WASH BOARD PATTERN

As this type of plate gap less metal contact, it is normally ap- plied to fluids containing fibers, particles or sludge. We have EXseries.


3.  SPECIAL PATTERN

YX plate is used exclusively for vapor condensation. GX plate is developed for heat transfer of fluids containing much slurry or high viscosity liquids.


HFM offers plates for all Hisaka Plate Heat Exchanger models below.


Model

Hisaka EX11

Hisaka EX15

Hisaka LX00A slit-in

Hisaka LX10A slit-in

Hisaka LX20

Hisaka LX20A slit-in

Hisaka LX30A slit-in

Hisaka LX40

Hisaka LX40A slit-in

Hisaka LX50A slit-in

Hisaka RX11A slit-in

Hisaka RX13A slit-in

Hisaka RX30A slit-in

Hisaka RX70

Hisaka SX41

Hisaka SX43

Hisaka SX90

Hisaka SX90M

Hisaka UX01

Hisaka UX10

Hisaka UX100

Hisaka UX10A slit-in

Hisaka UX20

Hisaka UX20A slit-in

Hisaka UX30

Hisaka UX30A slit-in

Hisaka UX40

Hisaka UX40A slit-in

Hisaka UX80

Hisaka UX90

Hisaka YX80




Hot Tags: plate for hisaka plate heat exchanger, China, suppliers, manufacturers
Related Products

Copyright © Hofmann (Beijing) Engineering Technology Co.,Ltd All Rights Reserved.